Search results
MCE40
40W convection cooled
87.9 x 38.1mm (3.46" x 1.5") footprint, 28.5mm profile
Regulated single outputs 3.3V to 48VDC
Input range 80 to 264VAC
Encapsulated or open frame formats
High efficiency, up to 88%
4kVAC input to output isolation
Class B conducted and radiated emissions
IEC 60601-1 medical safety agency approvals, 2 x MOPP
IEC class II insulation rating
Overvoltage, overload and short circuit protection
-25°C to +70°C operating temperature
3 year warranty
MCE20
- Regulated single outputs 3.3V to 48VDC
- Input range 80 to 264VAC
- Encapsulated or open frame formats
- High efficiency, up to 85%
- 4kVAC input to output isolation
- Class B conducted and radiated emissions
- IEC 60601-1 medical safety agency approvals, 2 x MOPP
- IEC class II insulation rating
- Overvoltage, overload and short circuit protection
- -25°C to +70°C operating temperature
- 3 year warranty
DDC15
- 4:1 DC input range 9V to 36VDC
- 3.3V to 24VDC outputs
- Low profile design
- 1.5kVDC isolation
- Class B conducted & radiated emissions
- High efficiency – up to 85%
- Ambient operation from -40°C to +70°C
- 3 year warranty
MCE10
- Regulated single outputs 3.3V to 48VDC
- Input range 80 to 264VAC
- Encapsulated or open frame formats
- High efficiency, up to 84%
- 4kVAC input to output isolation
- Class B conducted and radiated emissions
- IEC 60601-1 medical safety agency approvals, 2 x MOPP
- IEC class II insulation rating
- Overvoltage, overload and short circuit protection
- -25°C to +70°C operating temperature
- 3 year warranty
MCE03
- Regulated single outputs 3.3V to 48VDC
- Input range 80 to 264VAC
- Encapsulated or open frame formats
- High efficiency, up to 81%
- 4kVAC input to output isolation
- Class B conducted and radiated emissions
- IEC 60601-1 medical safety agency approvals, 2 x MOPP
- IEC class II insulation rating
- Overvoltage, overload and short circuit protection
- -25°C to +70°C operating temperature
- 3 year warranty
HCB200
0 to ±20kV bipolar output
4 quadrant operation with active load
Constant voltage control and current limitation with automatic transfer and control mode dispay with LED’s
Single phase AC input
Continuous operation at full rated power
Digital, LAN and USB interface option
Analog programming/interface option
Manual voltage control via 10 turn potentiometer
Digital display for current and voltage
Set-point display via a button
Set-point adjustment possible with disabled output
Push-button switch for output voltage
CE marked, EN61010-1 safety compliant
Short circuit & arc protection
2 year warranty
HCB140
0 to ±12.5kV bipolar output
4 quadrant operation with active load
Constant voltage control and current limitation with automatic transfer and control mode dispay with LED’s
Single phase AC input
Continuous operation at full rated power
Digital, LAN and USB interface option
Analog programming/interface option
Manual voltage control via 10 turn potentiometer
Digital display for current and voltage
Set-point display via a button
Set-point adjustment possible with disabled output
Push-button switch for output voltage
CE marked, EN61010-1 safety compliant
Short circuit & arc protection
2 year warranty
HCB70
0 to ±6.5kV bipolar output
4 quadrant operation with active load
Constant voltage control and current limitation with automatic transfer and control mode dispay with LED’s
Single phase AC input
Continuous operation at full rated power
Digital, LAN and USB interface option
Analog programming/interface option
Manual voltage control via 10 turn potentiometer
Digital display for current and voltage
Set-point display via a button
Set-point adjustment possible with disabled output
Push-button switch for output voltage
CE marked, EN61010-1 safety compliant
Short circuit & arc protection
2 year warranty
HCB35
0 to ±3.5kV bipolar output
4 quadrant operation with active load
Constant voltage control and current limitation with automatic transfer and control mode dispay with LED’s
Single phase AC input
Continuous operation at full rated power
Digital, LAN and USB interface option
Analog programming/interface option
Manual voltage control via 10 turn potentiometer
Digital display for current and voltage
Set-point display via a button
Set-point adjustment possible with disabled output
Push-button switch for output voltage
CE marked, EN61010-1 safety compliant
Short circuit & arc protection
2 year warranty
HCB20
0 to ±2kV - 0 to ±20kV bipolar output
4 quadrant operation with active load
Constant voltage control and current limitation with automatic transfer and control mode dispay with LED’s
Single phase AC input
Continuous operation at full rated power
Digital, LAN and USB interface option
Analog programming/interface option
Manual voltage control via 10 turn potentiometer
Digital display for current and voltage
Set-point display via a button
Set-point adjustment possible with disabled output
Push-button switch for output voltage
CE marked, EN61010-1 safety compliant
Short circuit & arc protection
2 year warranty