| EME055W | Regulated single outputs 3.3V to 48VDC Input range 85 to 264VAC Encapsulated or open frame PCB mount package Medical approvals (2 x MOPP) Class II Peak load capability No external components required 3 year warranty
| |
| ACM066W | Regulated single outputs 5V to 12VDC Energy efficiency level VI European CoC Tier 2 Medical & ITE approvals Interchangeable mains connectors Optional white versions Class II construction 3 year warranty
| |
| ACM1212W | Regulated single outputs 5V to 24VDC Energy efficiency level VI European CoC Tier 2 Medical & ITE approvals Interchangeable mains connectors Optional white versions Class II construction 3 year warranty
| |
| EML1515W | Regulated single outputs 3.3V to 48VDC Input range 85 to 264VAC Open frame or encapsulated PCB mount Open frame or encapsulated chassis mount Encapsulated DIN rail mount option Medical (2 x MOPP) approvals 3.0kVAC input to output isolation Class II construction Peak load capability No external components required <0.3W no load input power -25°C to +70°C operating temperature Full load to +50°C 3 year warranty
| |
| ACM1818W | Regulated single outputs 5V to 24VDC Energy efficiency level VI European CoC Tier 2 Medical & ITE approvals Interchangeable mains connectors Optional white versions Class II construction 3 year warranty
| |
| AMF1818W | Regulated single outputs 5V to 24VDC IP22 ingress protection IEC/EN60601-1-11 for home healthcare applications Energy efficiency level VI & EU2019/1782 Medical & home healthcare approvals Input voltage range 80 to 264VAC Interchangeable mains connectors Optional white versions Class II construction 3 year warranty
| |
| ACM2424W | Regulated single outputs 9V to 48Vdc Energy efficiency level VI European CoC tier 2 Medical & ITE approvals Interchangeable mains connectors Optional white versions Class II construction 3 year warranty
| |
| AMF2424W | Regulated single outputs 9V to 48VDC IP22 ingress protection IEC/EN60601-1-11 for home healthcare applications Energy efficiency level VI & EU2019/1782 Medical & home healthcare approvals Input voltage range 80 to 264VAC Interchangeable mains connectors Optional white versions Class II construction 3 year warranty
| |
| EML3030W | Regulated single outputs 3.3V to 48VDC Input range 85 to 264VAC Open frame or encapsulated PCB mount Open frame or encapsulated chassis mount Encapsulated DIN rail mount option Medical (2 x MOPP) approvals 3.0kVAC input to output isolation Class II construction Peak load capability No external components required <0.3W no load input power -25°C to +70°C operating temperature Full load to +50°C 3 year warranty
| |
| ACM3636W | Regulated single outputs 9V to 36VDC Energy efficiency level VI European CoC tier 2 Medical & ITE approvals Interchangeable mains connectors Optional white versions Class II construction 3 year warranty
| |
| AMF3636W | Regulated single outputs 5V to 48VDC Input voltage range 80 to 264VAC IP42 ingress protection IEC/EN60601-1-11 for home healthcare applications Energy efficiency level VI & EU2019/1782 Medical, home healthcare & ITE approvals Interchangeable mains connectors Optional white versions Class II construction 3 year warranty
| |
| AKM3636W | | |
| FCS4040W | 40W convection cooled 76.2 x 50.8mm (3" x 2") footprint, 26.4mm profile Regulated single outputs 12V to 48VDC Input range 80 to 264VAC Medical, ITE & household appliance approvals Class I & Class II installations Less than 0.3W no load input power 3 year warranty
| |
| ECF4040W |
- 40W convection cooled
- 76.2 x 38.1mm (3" x 1.5”) footprint, 28.0mm profile
- Regulated single outputs 12 to 48VDC
- Input range 80 to 264VAC
- Medical (2 x MOPP) & ITE approvals
- Class I & Class II installations
- Less than 0.15W no load input power
- 3 year warranty
| |
| AKM4545W | Regulated single outputs 9 to 48VDC Energy efficiency level VI European CoC Tier 2 Medical (2 x MOPP) & ITE approvals 4th edition medical EMC Class I as standard, Class II optional Class B conducted & radiated emissions Input voltage range 90 to 264VAC 0°C to +60°C operating temperature 3 year warranty
| |
| FCS6060W |
- 60W convection cooled
- 101.6 x 50.8mm (4" x 2") footprint, 26.4mm profile
- Regulated single outputs 12V to 48VDC
- input range 80 to 264VAC
- Medical, ITE & household appliance approvals
- Class I & Class II installations
- High power density
- Less than 0.3W no load input power
- 3 year warranty
| |
| AMF6060W | Output voltages from 12V to 24VDC Input voltage range 80 to 264VAC Energy efficiency level VI (level VII ready) & EU2019/1782 Medical, home healthcare & ITE safety approvals IP42 ingress protection Low patient leakage current <0.15W standby power Class B conducted & radiated emissions Class II construction 0 to +60°C operation 3 year warranty
| |
| PGW6565W | Output voltages from 5V to 20VDC Meets USB PD 3.0 & QC 4.0 / 3.0 / 2.0 fast charging protocol Universal, single phase input: 80 to 264VAC Energy efficiency level VI (VII ready) & EU2019/1782 Medical, home healthcare & ITE safety agency approvals IP42 environmental rating Low earth leakage current <0.15W standby power Class B conducted & radiated emissions 0 to +60°C operation 3 year warranty
| |
| ALM6565W | Regulated single outputs 12V to 48VDC Medical & ITE safety approvals Energy efficiency level VI 4th edition medical EMC IP32 environmental rating Class I & class II versions <0.21W standby power 0°C to +60°C operation Low earth leakage current 3 year warranty
| |
| AKM6565W | Regulated single outputs 12V to 48VDC Energy efficiency level VI European CoC tier 2 Medical (2 x MOPP) & ITE approvals Class I as standard, Class II optional Optional white versions Optional AC cable restraint 3 year warranty
| |