| CCR550PS24CCR550 Series | 550W fan cooled 450W conduction cooled 230W convection cooled 129.4 x 83.5mm (5.1" x 3.3") footprint, 25.4mm profile Single outputs 12V to 54VDC Input range 80 to 264VAC Medical (BF) and ITE approvals Low patient leakage <75μA Low earth leakage <300μA High efficiency, up to 94% Less than 0.5W no load input power -40°C to +80°C operation 3 year warranty
| |
| CCR550PS15CCR550 Series | 550W fan cooled 450W conduction cooled 230W convection cooled 129.4 x 83.5mm (5.1" x 3.3") footprint, 25.4mm profile Single outputs 12V to 54VDC Input range 80 to 264VAC Medical (BF) and ITE approvals Low patient leakage <75μA Low earth leakage <300μA High efficiency, up to 94% Less than 0.5W no load input power -40°C to +80°C operation 3 year warranty
| |
| CCR550PS12CCR550 Series | 550W fan cooled 450W conduction cooled 230W convection cooled 129.4 x 83.5mm (5.1" x 3.3") footprint, 25.4mm profile Single outputs 12V to 54VDC Input range 80 to 264VAC Medical (BF) and ITE approvals Low patient leakage <75μA Low earth leakage <300μA High efficiency, up to 94% Less than 0.5W no load input power -40°C to +80°C operation 3 year warranty
| |
| CCR420PS54CCR420 Series | 420W fan cooled 350W conduction cooled 225W convection cooled 129.4 x 83.5mm (5.1" x 3.3") footprint, 25.4mm profile Single outputs12 to 54VDC Input range 80 to 264VAC Medical (BF) and ITE approvals Low patient leakage <75μA Low earth leakage <300μA High efficiency, up to 94% Less than 0.5W no load input power -40°C to +80°C operation 3 year warranty
| |
| CCR420PS48CCR420 Series | 420W fan cooled 350W conduction cooled 225W convection cooled 129.4 x 83.5mm (5.1" x 3.3") footprint, 25.4mm profile Single outputs12 to 54VDC Input range 80 to 264VAC Medical (BF) and ITE approvals Low patient leakage <75μA Low earth leakage <300μA High efficiency, up to 94% Less than 0.5W no load input power -40°C to +80°C operation 3 year warranty
| |
| CCR420PS36CCR420 Series | 420W fan cooled 350W conduction cooled 225W convection cooled 129.4 x 83.5mm (5.1" x 3.3") footprint, 25.4mm profile Single outputs12 to 54VDC Input range 80 to 264VAC Medical (BF) and ITE approvals Low patient leakage <75μA Low earth leakage <300μA High efficiency, up to 94% Less than 0.5W no load input power -40°C to +80°C operation 3 year warranty
| |
| CCR420PS30CCR420 Series | 420W fan cooled 350W conduction cooled 225W convection cooled 129.4 x 83.5mm (5.1" x 3.3") footprint, 25.4mm profile Single outputs12 to 54VDC Input range 80 to 264VAC Medical (BF) and ITE approvals Low patient leakage <75μA Low earth leakage <300μA High efficiency, up to 94% Less than 0.5W no load input power -40°C to +80°C operation 3 year warranty
| |
| CCR420PS28CCR420 Series | 420W fan cooled 350W conduction cooled 225W convection cooled 129.4 x 83.5mm (5.1" x 3.3") footprint, 25.4mm profile Single outputs12 to 54VDC Input range 80 to 264VAC Medical (BF) and ITE approvals Low patient leakage <75μA Low earth leakage <300μA High efficiency, up to 94% Less than 0.5W no load input power -40°C to +80°C operation 3 year warranty
| |
| CCR420PS24CCR420 Series | 420W fan cooled 350W conduction cooled 225W convection cooled 129.4 x 83.5mm (5.1" x 3.3") footprint, 25.4mm profile Single outputs12 to 54VDC Input range 80 to 264VAC Medical (BF) and ITE approvals Low patient leakage <75μA Low earth leakage <300μA High efficiency, up to 94% Less than 0.5W no load input power -40°C to +80°C operation 3 year warranty
| |
| CCR420PS15CCR420 Series | 420W fan cooled 350W conduction cooled 225W convection cooled 129.4 x 83.5mm (5.1" x 3.3") footprint, 25.4mm profile Single outputs12 to 54VDC Input range 80 to 264VAC Medical (BF) and ITE approvals Low patient leakage <75μA Low earth leakage <300μA High efficiency, up to 94% Less than 0.5W no load input power -40°C to +80°C operation 3 year warranty
| |