CB3000 Series

RF Power

CB3000 Series

  • 3000 Watts
  • Small, lightweight packaging
  • Frequencies from 13.56 MHz to 60 MHz
  • Designed to meet ETL and SEMI F47 directives
  • LF class D\HF Class C or D amplifiers
  • Regulated Switch-mode DC Section
Contact us
Model Name Mains (VAC) Frequency Datasheet RFQ
CB3000 CB3000 208 / 400 / 480 VAC (3-Phase) 2 MHz

Specifications


Dimensions

17" W x 5.25" H x 16" D max. chassis dimensions 432mm x 133mm x 407mm

Input Voltage

187-230VAC, 400, or 480VAC; no neutral; 3 phase with ground.

Harmonic Currents

Less than -40dBc

Operating Temperature

+10 to +40 ° C (50 to 104 ° F) ambient, 5-85% R.H. (non-condensing, no formation of ice), 86-106 kPa. Temperature, humidity and air pressure operating range class 3K3 per prEN50178.

Isolation

2300 VDC minimum to the A/C supply line.

EMC

This unit is designed to meet the safety compliance requirements of EN 61010-1:2010, UL 61010-1:2012, and CSA C22.2 No. 61010-1:2012. Certified compliant systems carry the TUV mark for safety and/or EMC to all appropriate latest international standards.

Approval documents


No documents yet.

3D models


No documents yet.

Resources


No resourcess yet.