RF Power
CB5000 Series
- 5000 Watts
- Small, lightweight packaging
- Frequencies from 13.56 MHz to 60 MHz
- Designed to meet ETL and SEMI F47 directives
- LF class D\HF Class C or D amplifiers
- Regulated Switch-mode DC Section
Specifications
Dimensions
17"W x 5.25"H x 22"D ( 43.2cm x 13.4cm x 55.9cm)
Input Voltage
187-230VAC, 400, or 480VAC; no neutral; 3 phase with ground.
Harmonic Currents
Less than -40dBc
Operating Temperature
+10 to +40 ° C (50 to 104 ° F) ambient, 5-85% R.H. (non-condensing, no formation of ice), 86-106 kPa. Temperature, humidity and air pressure operating range class 3K3 per prEN50178.
Isolation
1000 VDC minimum to the A/C supply line.
EMC
This unit is designed to meet the safety compliance requirements of EN 61010-1:2010, UL 61010-1:2012, and CSA C22.2 No. 61010-1:2012. Certified compliant systems carry the TUV mark for safety and/or EMC to all appropriate latest international standards.
Approval documents
No documents yet.