Earth Leakage Current |
|
0.3 mA typical at 230 VAC 50 Hz |
 |
Input Protection |
|
None fitted (external 1 A slow blow type recommended) |
 |
Output Voltage Adjustment |
|
10% V1 dual output models only |
 |
Hold Up Time |
|
20/100 ms typical at 115/230 VAC input |
 |
Load Regulation |
|
±11.0% max single output models ±12.0% max dual output models (symmetrical load) |
 |
Ripple and Noise |
|
<100 mV pk-pk typical at 20 MHz bandwidth |
 |
Overload Protection |
|
130% of full load foldback automatic recovery |
 |
Short Circuit protection |
|
Long term short circuit not recommended |
 |
Isolation |
|
3000 VAC Input to Output 2000 VAC Input to Case 500 VAC Output to Case |
 |
MTBF |
|
>250 kHrs at 25 °C MIL-HDBK-217E |
 |
Weight |
|
PCB Models: TSU6 45g TSU10 75g TSU15 95g TSU25 135g; Chassis Mount Models: TSU10 80g TSU15 100g TSU25 150g; Screw Terminal Models: TSU15 105g TSU25 165g |
 |
Operating Temperature |
|
-25 °C to +60 °C derate 2.5%/°C above +40 °C for 5 V models 2.5%/°C above +50 °C all other models |
 |
Operating Humidity |
|
85% RH max non-condensing |
 |
Emissions |
|
EN55022 FCC & CISPR-22 all Level B conducted |
 |
ESD Susceptibility |
|
EN61000-4-2 Level 3 Air Perf Criteria B & Level 3 Contact Perf Criteria B |
 |
Radiated Susceptibility |
|
EN61000-4-3 10 V/m Perf Criteria A |
 |
EFT/Burst |
|
EN61000-4-4 Level 3 Perf Criteria B |
 |
Surge |
|
EN61000-4-5 Level 3 Perf Criteria B |
 |
Safety Approvals |
|
EN60950 UL/cUL1950 & IEC950 |