VEP24 Series

   
VEP24 Series • 24 Watts
• CEC2008 & EISA2007 Compliant
• Medical & ITE Approvals
• Interchangeable Input Connectors
• Class II Construction
• EN55022 Class B Emissions

Click Here for Model Numbers & Stock Check

Data/Approvals

 
 

short form datasheet Short Form Datasheet

Specifications  
 
Input
Input Voltage   90-264 VAC
Input Frequency   47-63 Hz
Input Current   0.6 A max at 90 VAC
Inrush Current   50 A max at 240 VAC
Power Factor   Conforms to EN61000-3-2, class A
No Load Input Power   <0.3 W
 
Output
Output Voltage   See datasheet
Initial Set Accuracy   ±5% at 50% load
Minimum Load   No minimum load required
Start Up Delay   2s max
Start Up Rise Time   50 ms typical
Hold Up Time   5 ms typical at full load and 115 VAC
Line Regulation   ±0.5% max
Load Regulation   ±5% max
Transient Response   4% max. deviation, recovery to <1% within 500 µs for a 50% step load change at 0.2 A/µs
Ripple & Noise   See datasheet
Overvoltage Protection   See datasheet
Overload Protection   120-280%, auto recovery
Short Circuit Protection   Trip and restart (Hiccup mode)
Temperature Coefficient   0.2 %/˚C
 
General
Efficiency   See datasheet
Isolation   4000 VAC Input to Output
Switching Frequency   65 kHz typical
MTBF   >250 kHrs per MIL-HDBK-217F at 25ºC
 
Environmental
Operating Temperature   0 ˚C to +40 ˚C
Cooling   Natural convection
Operating Humidity   5-95% RH, non-condensing
Storage Temperature   -20 ˚C to +60 ˚C
Shock   Able to survive 1m drop onto concrete on each of 6 axes
Vibration   10-300 Hz, 2 g 15 mins/sweep. 30 mins for each of 3 axes
 
EMC and Safety
Emissions   EN55022, level B conducted & radiated
Harmonic Currents   EN61000-3-2, class A
Voltage Flicker   EN61000-3-3
ESD Immunity   EN61000-4-2, ±4kV contact, ±8kV air, Perf Criteria A
Radiated Immunity   EN61000-4-3, 3 V/m, Perf Criteria A
EFT/Burst   EN61000-4-4, level 2, Perf Criteria A
Surge   EN61000-4-5, level 3, Perf Criteria A
Conducted Immunity   EN61000-4-6, 3 V, Perf Criteria A
Magnetic Field   EN61000-4-8, 1 A/m, Perf Criteria A
Dips & Interruptions   EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B
Safety Approvals   EN60950, UL60950-1, IEC60950-1, CSA 60950-1-03, EN60601-1, UL60601-1, IEC60601-1, CSA C22.2 No 601.1, China Compulsory Certification (CCC) Qualified
           
Model Number
Input
Output
Power
       
  VEP24US05 90-264 VAC 5.0 V/2.5 A 12.5 WStock Check
  VEP24US09 90-264 VAC 9.0 V/2.2 A 19.8 WStock Check
  VEP24US12 90-264 VAC 12.0 V/2.0 A 24 WStock Check
  VEP24US15 90-264 VAC 15.0 V/1.6 A 24 W 
  VEP24US24 90-264 VAC 24.0 V/1.0 A 24 WStock Check
           


Defence & Avionics Communications Medical

Industrial

Engineered Solutions