Specifications |
|
| |
Input |
 |
Input Voltage |
|
90-264 VAC
|
 |
Input Frequency |
|
47-63 Hz
|
 |
Input Current |
|
0.6 A max at 90 VAC |
 |
Inrush Current |
|
50 A max at 240 VAC |
 |
Power Factor |
|
Conforms to EN61000-3-2, class A
|
 |
No Load Input Power |
|
<0.3 W
|
| |
Output |
 |
Output Voltage |
|
See datasheet |
 |
Initial Set Accuracy |
|
±5% at 50% load |
 |
Minimum Load |
|
No minimum load required
|
 |
Start Up Delay |
|
2s max
|
 |
Start Up Rise Time |
|
50 ms typical
|
 |
Hold Up Time |
|
5 ms typical at full load and 115 VAC |
 |
Line Regulation |
|
±0.5% max
|
 |
Load Regulation |
|
±5% max
|
 |
Transient Response |
|
4% max. deviation, recovery to <1% within 500 µs for a 50% step load change at 0.2 A/µs
|
 |
Ripple & Noise |
|
See datasheet |
 |
Overvoltage Protection |
|
See datasheet |
 |
Overload Protection |
|
120-280%, auto recovery |
 |
Short Circuit Protection |
|
Trip and restart (Hiccup mode) |
 |
Temperature Coefficient |
|
0.2 %/˚C |
| |
General |
 |
Efficiency |
|
See datasheet |
 |
Isolation |
|
4000 VAC Input to Output |
 |
Switching Frequency |
|
65 kHz typical
|
 |
MTBF |
|
>250 kHrs per MIL-HDBK-217F at 25ºC |
| |
Environmental |
 |
Operating Temperature |
|
0 ˚C to +40 ˚C |
 |
Cooling |
|
Natural convection |
 |
Operating Humidity |
|
5-95% RH, non-condensing |
 |
Storage Temperature |
|
-20 ˚C to +60 ˚C
|
 |
Shock |
|
Able to survive 1m drop onto concrete on each of 6 axes
|
 |
Vibration |
|
10-300 Hz, 2 g 15 mins/sweep. 30 mins for each of 3 axes
|
| |
EMC and Safety |
 |
Emissions |
|
EN55022, level B conducted & radiated |
 |
Harmonic Currents |
|
EN61000-3-2, class A
|
 |
Voltage Flicker |
|
EN61000-3-3 |
 |
ESD Immunity |
|
EN61000-4-2, ±4kV contact, ±8kV air,
Perf Criteria A |
 |
Radiated Immunity |
|
EN61000-4-3, 3 V/m, Perf Criteria A
|
 |
EFT/Burst |
|
EN61000-4-4, level 2, Perf Criteria A
|
 |
Surge |
|
EN61000-4-5, level 3, Perf Criteria A
|
 |
Conducted Immunity |
|
EN61000-4-6, 3 V, Perf Criteria A |
 |
Magnetic Field |
|
EN61000-4-8, 1 A/m, Perf Criteria A
|
 |
Dips & Interruptions |
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B
|
 |
Safety Approvals |
|
EN60950, UL60950-1, IEC60950-1,
CSA 60950-1-03, EN60601-1, UL60601-1, IEC60601-1, CSA C22.2 No 601.1, China Compulsory Certification (CCC) Qualified |
| |
|
|
|
|
|
|
Model Number |
Input |
Output |
Power |
|
|
|
|
|
|
|
| |
VEP24US05 |
90-264 VAC |
5.0 V/2.5 A |
12.5 W | Stock Check |
| |
VEP24US09 |
90-264 VAC |
9.0 V/2.2 A |
19.8 W | Stock Check |
| |
VEP24US12 |
90-264 VAC |
12.0 V/2.0 A |
24 W | Stock Check |
| |
VEP24US15 |
90-264 VAC |
15.0 V/1.6 A |
24 W | |
| |
VEP24US24 |
90-264 VAC |
24.0 V/1.0 A |
24 W | Stock Check |
| |
|
|
|
|
|
|