Specifications |
|
| |
Input |
 |
Input Voltage Range |
|
90-264 VAC
|
 |
Input Frequency |
|
47-63 Hz |
 |
Inrush Current |
|
20 A pk max, cold start 25 ºC |
 |
Power Factor |
|
Compliant with EN61000-3-2 |
 |
Input Protection |
|
P3/M3: Internal T5 A/250 V fuse in line
P4/M4: Internal T6.3 A/250 V fuse in line
P5/M5: Internal T10 A/250 V fuse in line.
M versions include fuse in neutral
|
| |
Output |
 |
Output Voltage |
|
See datasheet
|
 |
Output Voltage Trim |
|
±10 % min all modules. See datasheet for extended adjustment range
|
 |
Hold Up Time |
|
20 ms min |
 |
Line Regulation |
|
Typically 0.1%, maximum 0.3% |
 |
Load Regulation |
|
1% max for single output modules & V1 of dual & triple output modules
2% max for V2 & V3 of dual & triple output modules
A 10% load must be applied to output 1 of the high current dual module (U) & triple module (T) to achieve this figure
|
 |
Ripple & Noise |
|
50 mV or 1% pk-pk, whichever is greater, 20 MHz bandwidth
|
 |
Overvoltage Protection |
|
120-130% Vnom for single output &
output 1 of high current dual modules (U) & triple modules (T)
|
 |
Overload Protection |
|
<140% of nominal rating |
 |
Short Circuit Protection |
|
Foldback
|
 |
Temperature Coefficient |
|
0.03%/°C
|
 |
Remote Sense |
|
Compensates for up to 0.5 V drop on
single (S) output modules & output 1
of dual (U) & triple (T) output modules
|
 |
Current Share |
|
Single wire parallel current share. See
signals & controls page on datasheet |
| |
General |
 |
Efficiency |
|
75% typical at nominal input |
 |
Isolation |
|
4000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground |
 |
Signals & Controls |
|
AC OK, DC OK, Global & Module Inhibit.
See signals & controls page |
 |
MTBF |
|
890 kHrs demonstrated |
 |
Switching Frequency |
|
60 kHz typical PFC, 200 kHz typical modules |
| |
Environmental |
 |
Operating Temperature |
|
0 °C to +70 °C, derate linearly from 100% at +50 °C to 50% at +70 °C for fan versions. See airflow curves for U-channel versions.
|
 |
Storage Temperature |
|
-40 °C to +85 °C
|
 |
Operating Altitude |
|
3000 m
|
 |
Shock |
|
30 g, 11 ms (half sine), 3 shocks each axis, 18 shocks total. Compliant with EN60068-2-27
|
 |
Vibration |
|
2 g, 10-500 Hz, 10 sweeps 3 axes.
Compliant with EN60068-2-27 |
| |
EMC and Safety |
 |
Emissions |
|
LP models P3-P5: EN55022, level B conducted
LP-MD models, M3-M5: EN55011, level A conducted with FE(x) cover, M(x) level B conducted with ME(x) cover |
 |
Harmonic Currents |
|
EN61000-3-2, Class A |
 |
Voltage Flicker |
|
EN61000-3-3 |
 |
ESD Immunity |
|
EN61000-4-2, level 3 Perf Criteria A |
 |
Radiated Immunity |
|
EN61000-4-3, level 3 Perf Criteria A |
 |
EFT/Burst |
|
EN61000-4-4, level 3 Perf Criteria A |
 |
Surge |
|
EN61000-4-5, level 3 Perf Criteria A |
 |
Conducted Immunity |
|
EN61000-4-6, level 3 Perf Criteria A
|
 |
Dips & Interruptions |
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Criteria A, B, B
|
 |
Safety Approvals |
|
LP models: EN60950, UL60950, CSA22.2 No 950, CE Mark LVD, SEMI F47
compliant (highline only)
LP-MD models: EN60601-1, CSA22.2-601, UL60601-1, CE Mark LVD
|