Specifications |
|
| |
Input |
 |
Input Voltage Range |
|
12 V (9-18 VDC)
24 V (18-36 VDC)
48 V (36-75 VDC) |
 |
Input Current |
|
See table on datasheet |
 |
Input Reflected Ripple Current |
|
20 mA rms through 12 µH inductor, 5 Hz to 20 MHz
|
 |
Under Voltage Lockout |
|
12 V models On 8.6 V, Off 7.9 V typical
24 V models On 17.8 V, Off 16 V typical
48 V models On 33.5 V, Off 30.5 V typical |
 |
Input Surge |
|
12 V models 30 VDC for 100 ms
24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
|
 |
Isolation Resistance |
|
109Ω min |
| |
Output |
 |
Output Voltage |
|
See table on datasheet |
 |
Minimum Load |
|
No minimum load required
|
 |
Line Regulation |
|
±0.5% max
|
 |
Load Regulation |
|
±0.5% max for single and dual outputs except ±0.8% for D03 versions
|
 |
Cross Regulation |
|
±5% max on dual output models, see note 2
|
 |
Setpoint Accuracy |
|
±1.0% max |
 |
Start Up Delay |
|
<20 ms
|
 |
Start Up Rise Time |
|
<5 ms
|
 |
Ripple & Noise |
|
75 mV pk-pk max, see note 3 of datasheet |
 |
Transient Response |
|
±3% max deviation, recovery to within 1% in 250 µs for a 25% load change |
 |
Temperature Coefficient |
|
0.02%/°C |
 |
Overcurrent Protection |
|
>140% of full load at nominal input
|
 |
Short Circuit Protection |
|
Trip & restart (Hiccup mode) with auto recovery |
 |
Capacitive Load |
|
See table |
| |
General |
 |
Efficiency |
|
See table on datasheet |
 |
Isolation Voltage |
|
1500 VDC Input to Output,
optional 3500 V, see note 4
1500 VDC Input to Case
1500 VDC Output to Case |
 |
Isolation Capacitance |
|
1200 pF typical |
 |
Switching Frequency |
|
300 kHz typical
|
 |
MTBF |
|
>1.1 MHrs to MIL-HDBK-217F at 25 ºC, GB
|
| |
Environmental |
 |
Operating Temperature |
|
-40 °C to +100 °C, derate from 100% load at +70 °C to 0% load at +100 °C
|
 |
Case Temperature |
|
+100 °C max |
 |
Storage Temperature |
|
-40 °C to +125 °C |
 |
Cooling |
|
Convection-cooled
|
 |
Operating Humidity |
|
Up to 95% RH, non-condensing
|
| |
EMC and Safety |
 |
Emissions |
|
EN55022, Class A conducted
& radiated with external components,
see application note
|
 |
ESD Immunity |
|
EN61000-4-2, 8 kV air, 6 kV contact,
Perf Criteria A
|
 |
Radiated Immunity |
|
EN61000-4-2, 8 kV air, 6 kV contact,
Perf Criteria A
|
 |
EFT/Burst |
|
EN61000-4-4 level 3, Perf Criteria B*
(*External input capacitor required 220 µF/100 V) |
 |
Surge |
|
EN61000-4-5 level 2, Perf Criteria B*
*External input capacitor required 220 µF/100 V)
|
 |
Conducted Immunity |
|
EN61000-4-6 10 V/rms,Perf Criteria A |
 |
Magnetic Fields |
|
EN61000-4-8 1 A/m, Perf Criteria A |