Specifications |
|
| |
Input |
 |
Input Voltage |
|
90-264 VAC |
 |
Input Frequency |
|
47-63 Hz |
 |
Input Current |
|
100 W: 1.2 A at 115 VAC, 0.55 A at 230 VAC,
120 W: 1.4 A at 115 VAC, 0.63 A at 230 VAC,
150 W: 2.0 A at 115 VAC, 0.80 A at 230 VAC |
 |
Power Factor |
|
0.95 typical |
 |
Earth Leakage Current |
|
200 µA max at 115 VAC,
400 µA max at 230 VAC
(except C2 version) |
 |
No Load Input Power |
|
<0.5 W |
| |
Output |
 |
Output Voltage Trim |
|
See table on datasheet |
 |
Output Voltage Trim |
|
Not user-adjustable |
 |
Initial Set Accuracy |
|
See note 3 on datasheet
|
 |
Minimum Load |
|
No minimum load required
|
 |
Start Up Delay |
|
2 s max at 100 VAC |
 |
Start Up Rise Time |
|
25 ms max |
 |
Hold Up Time |
|
100 W & 120 W: 16 ms minimum at 90 VAC
150 W: 9 ms minimum at 90 VAC |
 |
Line Regulation |
|
±0.5% maximum |
 |
Load Regulation |
|
See table on datasheet
|
 |
Transient Response |
|
5% max. deviation, recovery to within
1% in 10 ms for a 50% load change |
 |
Ripple & Noise |
|
1.5% max pk-pk (see note 1 on datasheet)
|
 |
Overvoltage Protection |
|
110-140% Vnom, recycle input to reset
|
 |
Overtemperature Protection |
|
Unit shuts down, recycle input to reset
|
 |
Overload Protection |
|
125% typical, auto recovery
|
 |
Short Circuit Protection |
|
Trip and restart (Hiccup mode) |
 |
Temperature Coefficient |
|
0.04%/°C |
| |
General |
 |
Efficiency |
|
See table on datasheet |
 |
Isolation |
|
3000 VAC Input to Output
1500 VAC Input to Ground (not C2 version)
Output 0 V and connector shell are
electrically connected to Input Ground
(not C2 version) |
 |
Switching Frequency |
|
PFC 30-90 kHz variable
PWM 100-120 kHz typical
|
 |
Power Density |
|
5.95 W/In3 for 150 W |
 |
MTBF |
|
>150 kHrs to MIL-HDBK-217F at 25 ºC, GB
|
| |
Environmental |
 |
Operating Temperature |
|
0 °C to +50 °C, derate from 100% power
at +40 °C to 75% power at +50 °C
|
 |
Operating Humidity |
|
10-95% RH, non-condensing |
 |
Storage Temperature |
|
-20 °C to +80 °C |
 |
Operating Altitude |
|
2000 m |
 |
Shock |
|
30 g, 10 ms on 3 axes |
 |
Vibration |
|
5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
|
| |
EMC and Safety |
 |
Emissions |
|
EN55022, Class B conducted and radiated |
 |
Harmonic Currents |
|
EN61000-3-2, Class A
|
 |
Voltage Flicker |
|
EN61000-3-3 |
 |
ESD Immunity |
|
EN61000-4-2, 8 kV air, 4 kV contact, Perf Criteria A |
 |
Radiated Immunity |
|
EN61000-4-3, level 2 Perf Criteria A |
 |
EFT/Burst |
|
EN61000-4-4, level 2 Perf Criteria A
|
 |
Surge |
|
EN61000-4-5, level 2 Perf Criteria A |
 |
Conducted Immunity |
|
EN61000-4-6, level 2 Perf Criteria A |
 |
Dips & Interruptions |
|
EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
|
 |
Safety Approvals |
|
EN60950-1, cUL60950-1
|