Specifications |
|
| |
Input |
 |
Input Voltage |
|
80-264 VAC, derate output power
10% <90 VAC and 20% <85 VAC |
 |
Input Frequency |
|
47-63 Hz |
 |
Input Current |
|
6.5 A at 115 VAC typical
3.2 A at 230 VAC with 650 W load |
 |
Power Factor |
|
EN61000-3-2 class A compliant |
 |
Earth Leakage Current |
|
250 µA max 264 VAC 60 Hz |
 |
Input Protection |
|
T 16 A / 250 V internal fuse in line and neutral
|
| |
Output |
 |
Output Voltage |
|
12-48 VDC (see tables) |
 |
Output Voltage Trim |
|
±10% V1
|
 |
Initial Set Accuracy |
|
±1% V1, ±5% V3
|
 |
Minimum Load |
|
No minimum load required |
 |
Start Up Delay |
|
500 ms max |
 |
Start Up Rise Time |
|
50 ms typical |
 |
Hold Up Time |
|
20 ms minimum
|
 |
Drift |
|
±0.2% after 20 min warm up |
 |
Line Regulation |
|
±0.5% maximum
|
 |
Load Regulation |
|
±1% V1, ±5% V3 |
 |
Transient Response |
|
4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change
|
 |
Ripple & Noise |
|
1% pk-pk V1, 20 MHz bandwidth |
 |
Overvoltage Protection |
|
115-145% Vnom, recycle input to reset |
 |
Overtemperature Protection |
|
Auto reset
|
 |
Overload Protection |
|
110-140%, V1 only |
 |
Short Circuit Protection |
|
Auto recovery |
 |
Temperature Coefficient |
|
0.05% / ºC |
 |
Remote Sense |
|
Compensates for 0.5 V total voltage drop
|
 |
Remote On/Off |
|
Uncommitted isolated optocoupler diode, powered diode inhibits V1 & V2 fan supply |
 |
Current Share |
|
Single wire current share |
| |
General |
 |
Efficiency |
|
86% typical |
 |
Isolation |
|
4000 VAC input to output, 1500 VAC input to ground, 500 VDC output to ground |
 |
Switching Frequency |
|
PFC 70 KHz, main converter 200 KHz |
 |
Power Density |
|
8.2 W/in3 |
 |
Signals |
|
AC OK, remote on/off, current share |
 |
MTBF |
|
300 KHrs to MIL-HDBK-217 at 25 ºC, GB |
| |
Environmental |
 |
Operating Temperature |
|
-20 °C to +70 °C, derate linearly from +50 ºC at 2.5% / ºC to 50% load at +70 ºC
|
 |
Cooling |
|
Forced cooled, ‘-TF’ & ‘-EF’ models have integral dual voltage level fan, which is load dependant, U Channel requires 5.5 m/s minimum airflow |
 |
Operating Humidity |
|
95% RH, non-condensing |
 |
Storage Temperature |
|
-40 °C to +85 °C
|
 |
Operating Altitude |
|
3000 m |
 |
Shock |
|
30 g pk, half sine, 6 axes |
 |
Vibration |
|
2 g rms, 5 Hz to 500 kHz, 3 axes
|
| |
EMC and Safety |
 |
Emissions |
|
EN55022 level B conducted, EN55022 level A radiated |
 |
Harmonic Currents |
|
EN61000-3-2, class A
|
 |
Voltage Flicker |
|
EN61000-3-3 |
 |
Radiated Immunity |
|
EN61000-4-3, level 3 Perf Criteria A |
 |
EFT/Burst |
|
EN61000-4-4, level 3 Perf Criteria A |
 |
Surge |
|
EN61000-4-5, installation class 3, Perf Criteria A
|
 |
Conducted Immunity |
|
EN61000-4-6, level 3, Perf Criteria A |
 |
Dips & Interruptions |
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B, EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - 230 VAC. Consult longform datasheet for 115 V operation.
|
 |
Safety Approvals |
|
IEC60601-1 CB report, CSA 22.2 No. 60601-1, UL60601-1, TUV, EN60601-1 |