Specifications |
|
| |
Input |
 |
Input Voltage |
|
80-264 VAC (120-370 VDC), see derating curve on datasheet |
 |
Input Frequency |
|
47-400 Hz, see note 1 on datasheet
|
 |
Input Current |
|
0.75 A typical at 115 VAC, full load
0.45 A typical at 230 VAC, full load |
 |
Inrush Current |
|
40 A max at 230 VAC, cold start 25 ºC |
 |
Power Factor |
|
EN61000-3-2, class A
|
 |
No Load Input Power |
|
US05, 12 & 24 models <0.3 W, US48 <0.5 W |
 |
Earth Leakage Current |
|
260 μA at 264 VAC/60 Hz max,
80/160 μA typical 115/230 VAC |
 |
Input Protection |
|
T3.15 A/250 V internal fuse in line
and neutral |
| |
Output |
 |
Output Voltage |
|
05-48 VDC (see tables) |
 |
Output Voltage Trim |
|
±10% |
 |
Initial Set Accuracy |
|
±1%
|
 |
Minimum Load |
|
No miniumum load required
|
 |
Start Up Delay |
|
1 s typical
|
 |
Start Up Rise Time |
|
50 ms |
 |
Hold Up Time |
|
16 ms min at 115 VAC
|
 |
Drift |
|
±0.2% after 20 min warm up |
 |
Line Regulation |
|
±0.5% max |
 |
Load Regulation |
|
±1% |
 |
Over/Undershoot |
|
5% typical |
 |
Transient Response |
|
4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load change
|
 |
Ripple & Noise |
|
1% pk-pk V1, 20 MHz bandwidth |
 |
Overvoltage Protection |
|
115-140% Vnom, recycle input to reset |
 |
Overload Protection |
|
110-200% |
 |
Short Circuit Protection |
|
Continuous trip and restart (Hiccup mode)
|
 |
Temperature Coefficient |
|
0.05%/˚C |
| |
General |
 |
Efficiency |
|
87% typical |
 |
Isolation Capacitance |
|
4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground |
 |
Switching Frequency |
|
65 KHz typical |
 |
Power Density |
|
7.9 W/in3 |
 |
MTBF |
|
1072 kHrs to MIL-HDBK-217F at 25 °C, GB |
| |
Environmental |
 |
Operating Temperature |
|
-20 °C to +70 °C derate linearly from +50 °C
at 2.5%/°C to 50% load at +70 °C. |
 |
Cooling |
|
Convection |
 |
Operating Humidity |
|
95% RH, non-condensing |
 |
Storage Temperature |
|
-40 ˚C to +85 ˚C |
 |
Operating Altitude |
|
3000 m |
 |
Shock |
|
30 g pk, half sine, 6 axes |
 |
Vibration |
|
2 g rms, 5 Hz to 500 kHz, 3 axes |
| |
EMC and Safety |
 |
Low Voltage PSU EMC |
|
EN61204-3, high severity level as below |
 |
Emissions |
|
EN55022 level B conducted
EN55022 level A radiated ECS45,
Level B ECS25 |
 |
Harmonic Currents |
|
EN61000-3-2, class A
|
 |
Voltage Flicker |
|
EN61000-3-3 |
 |
Radiated Immunity |
|
EN61000-4-3, level 3 Perf Criteria A |
 |
EFT/Burst |
|
EN61000-4-4, level 3 Perf Criteria A |
 |
Surge |
|
EN61000-4-5, installation class 3
Perf Criteria A
|
 |
Conducted Immunity |
|
EN61000-4-6, level 3 Perf Criteria A
|
 |
Dips & Interruptions |
|
EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria
A, A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation. |
 |
Safety Approvals |
|
EC60950-1 CB report, UL60950-1,
TUV EN60950-1
IEC60601-1 CB report, UL60601-1,
TUV 60601-1 |
 |
Equipment Protection Class |
|
Class I and Class II
|