ECS25-45 Series

   
ECS25-45 Series • 25 & 45 Watts
• Very Small 3” x 2” x 0.95” Package
• <0.3 W Standby Power
• 25 & 45 W - Convection Cooled Rating
• Class I & Class II Construction
• 3 Year Warranty

Click Here for Model Numbers & Stock Check
Specifications  
 
Input
Input Voltage   80-264 VAC (120-370 VDC), see derating curve on datasheet
Input Frequency   47-400 Hz, see note 1 on datasheet
Input Current   0.75 A typical at 115 VAC, full load 0.45 A typical at 230 VAC, full load
Inrush Current   40 A max at 230 VAC, cold start 25 ºC
Power Factor   EN61000-3-2, class A
No Load Input Power   US05, 12 & 24 models <0.3 W, US48 <0.5 W
Earth Leakage Current   260 μA at 264 VAC/60 Hz max, 80/160 μA typical 115/230 VAC
Input Protection   T3.15 A/250 V internal fuse in line and neutral
 
Output
Output Voltage   05-48 VDC (see tables)
Output Voltage Trim   ±10%
Initial Set Accuracy   ±1%
Minimum Load   No miniumum load required
Start Up Delay   1 s typical
Start Up Rise Time   50 ms
Hold Up Time   16 ms min at 115 VAC
Drift   ±0.2% after 20 min warm up
Line Regulation   ±0.5% max
Load Regulation   ±1%
Over/Undershoot   5% typical
Transient Response   4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change
Ripple & Noise   1% pk-pk V1, 20 MHz bandwidth
Overvoltage Protection   115-140% Vnom, recycle input to reset
Overload Protection   110-200%
Short Circuit Protection   Continuous trip and restart (Hiccup mode)
Temperature Coefficient   0.05%/˚C
 
General
Efficiency   87% typical
Isolation Capacitance   4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground
Switching Frequency   65 KHz typical
Power Density   7.9 W/in3
MTBF   1072 kHrs to MIL-HDBK-217F at 25 °C, GB
 
Environmental
Operating Temperature   -20 °C to +70 °C derate linearly from +50 °C at 2.5%/°C to 50% load at +70 °C.
Cooling   Convection
Operating Humidity   95% RH, non-condensing
Storage Temperature   -40 ˚C to +85 ˚C
Operating Altitude   3000 m
Shock   30 g pk, half sine, 6 axes
Vibration   2 g rms, 5 Hz to 500 kHz, 3 axes
 
EMC and Safety
Low Voltage PSU EMC   EN61204-3, high severity level as below
Emissions   EN55022 level B conducted EN55022 level A radiated ECS45, Level B ECS25
Harmonic Currents   EN61000-3-2, class A
Voltage Flicker   EN61000-3-3
Radiated Immunity   EN61000-4-3, level 3 Perf Criteria A
EFT/Burst   EN61000-4-4, level 3 Perf Criteria A
Surge   EN61000-4-5, installation class 3 Perf Criteria A
Conducted Immunity   EN61000-4-6, level 3 Perf Criteria A
Dips & Interruptions   EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B, EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - 230 VAC. Consult longform datasheet for 115 V operation.
Safety Approvals   EC60950-1 CB report, UL60950-1, TUV EN60950-1 IEC60601-1 CB report, UL60601-1, TUV 60601-1
Equipment Protection Class   Class I and Class II
           
Model Number
Input
Output
Power
       
  ECS25US12 80-264 V 12 V/2.08 A 25 WStock Check
  ECS25US15 80-264 V 15 V/1.67 A 25 WStock Check
  ECS25US24 80-264 V 24 V/1.04 A 25 WStock Check
  ECS25US48 80-264 V 48 V/0.52 A 25 WStock Check
  ECS45US05 80-264 V 5 V/6 A 30 WStock Check
  ECS45US12 80-264 V 12 V/3.75 A 45 WStock Check
  ECS45US15 80-264 V 15 V/3 A 45 WStock Check
  ECS45US24 80-264 V 24 V/1.9 A 45 WStock Check
  ECS45US48 80-264 V 48 V/0.95 A 45 WStock Check
           


Defence & Avionics Communications Medical