Input Protection |
|
Fitted with a T2 A/250 VAC fuse in live line |
 |
Transient Response |
|
5% max deviation recovering to within 1% within 500 µs for 50% load change
|
 |
Ripple & Noise |
|
1% max, 20 MHz BW see note 2
|
 |
Short Circuit Protection |
|
Trip & restart (hiccup mode), auto-recovery
|
 |
Operating Temperature |
|
0 °C to +60 °C, derate from 100% load at +40 °C to 50% load at +60 °C |
 |
Vibration |
|
5-500 Hz at 3 g for 10 mins on each axis |
 |
Shock |
|
30 g with 18 ms half sine wave, 3 times on each axis
|
 |
Emissions |
|
EN55011 Level B conducted & radiated |
 |
ESD Immunity |
|
EN61000-4-2 Level 3, Perf Criteria A
|
 |
Radiated Immunity |
|
EN61000-4-3 Level 2, Perf Criteria A
|
 |
EFT/Burst |
|
EN61000-4-4, Level 3, Perf Criteria A
|
 |
Surge |
|
EN61000-4-5 Level 3, Perf Criteria A |
 |
Conducted Immunity |
|
EN61000-4-6 Level 3, Perf Criteria A
|
 |
Dips & Interruptions |
|
EN61000-4-11, 70% UT for 500 ms, 40% UT for 100 ms, <5% UT for 5000 ms, Perf criteria A, B, B |
 |
Safety Approvals |
|
UL60601-1, EN60601-1, IEC60601-1, CE Mark |