Specifications  
 
Input
Input Voltage Range   24 V (9-36 VDC) 48 V (18-75 VDC)
Input Current   See datasheet
Undervoltage Lockout   24 V models: ON 8.6 V, OFF 7.9 V typical, 48 V models: ON 17.8 V, OFF 16 V typical
Input Surge   24 V models 50 VDC for 100 ms 48 V models 100 VDC for 100 ms
 
Output
Input Current   See datasheet
Output Voltage Trim   ±10%, single outputs
Minimum Load   No minimum load required
Line Regulation   ±0.5% max
Load Regulation   Single output models: ±0.5% max Dual output models: ±1% max balanced outputs
Cross Regulation   ±5% for dual outputs, see datasheet - note 2 on datasheet
Setpoint Accuracy   ±1%
Start Up Time   20 ms typical
Ripple & Noise   75 mV pk-pk at 20 MHz bandwidth, see note 3 on datasheet
Transient Response   3% max deviation, recovery to within 1% in <250 µs for a 25% load change
Temperature Coefficient   0.02%/°C
Overvoltage Protection   3.3 V models: 3.9 V typical 5 V models: 6.2 V typical 12 V models: 15 V typical 15 V models: 18 V typical ±5 V models: ±6.2 V typical ±12 V models: ±15 V typical ±15 V models: ±18 V typical
Overload Protection   >120% of full load typical
Short Circuit Protection   Trip & restart (Hiccup mode), auto recovery
Remote On/Off   On = Logic High (3.0-12.0 V) or Open Off = Logic Low (<1.2 V) or short pin 2 to 6 see note 4 of datasheet
 
General
Efficiency   See datasheet
Isolation   1600 VDC Input to Output 1600 VDC Input to Case 1600 VDC Output to Case
Switching Frequency   330 kHz typical
MTBF   560 kHrs min to MIL-HDBK-217F at 25 ºC, GB
 
Environmental
Operating Temperature   -40 °C to +105 °C, See derating curve on datasheet
Case Temperature   +105 °C max
Cooling   Convection-cooled
Operating Humidity   5-95% RH, non-condensing
Storage Temperature   -40 °C to +125 °C
 
EMC and Safety
Emissions   EN55022, class A conducted & radiated with external components - see application notes on datasheet
ESD Immunity   EN61000-4-2, level 3 Perf Criteria A
Radiated Immunity   EN61000-4-3 10 V/m, Perf Criteria A
EFT/Burst   EN61000-4-4 level 3, Perf Criteria B* (*External input capacitor required 220 µF/100 V)
Surge   EN61000-4-5 level 2, Perf Criteria B* (*External input capacitor required 220 µF/100 V)
Conducted Immunity   EN61000-4-6 10 V/rms, Perf Criteria A
Magnetic Field   EN61000-4-8 1 A/m, Perf Criteria A
Safety Approvals   EN60950-1, IEC60950-1
           
Model Number
Input
Output
Power
       
  JTM2024D05 9-36 V ±5V/±2 20Stock Check
  JTM2024D12 9-36 V ±12/±0.835 20Stock Check
  JTM2024D15 9-36 V ±15/±0.665 20Stock Check
  JTM2024S05 9-36 V 5V/4A 20Stock Check
  JTM2024S12 9-36 V 12V/1.67A 20Stock Check
  JTM2024S15 9-36 V 15V/1.33A 20Stock Check
  JTM2024S3V3 9-36 V 3.3V/5.5A 20Stock Check
  JTM2048D05 18-75 V ±5V/±2A 20Stock Check
  JTM2048D12 18-75 V ±12V/±0.835A 20Stock Check
  JTM2048D15 18-75 V ±15V/±0.665A 20Stock Check
  JTM2048S05 18-75 V 5V/4A 20Stock Check
  JTM2048S12 18-75 V 12V/1.67A 20Stock Check
  JTM2048S15 18-75 V 15V/1.33A 20Stock Check
  JTM2048S3V3 18-75 V 3.3V/5.5A 20Stock Check
           