Specifications |
|
| |
Input |
 |
Input Voltage Range |
|
24 V (9-36 VDC) 48 V (18-75 VDC) |
 |
Input Current |
|
See datasheet |
 |
Undervoltage Lockout |
|
24 V models: ON 8.6 V, OFF 7.9 V typical, 48 V models: ON 17.8 V, OFF 16 V typical |
 |
Input Surge |
|
24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
|
| |
Output |
 |
Input Current |
|
See datasheet |
 |
Output Voltage Trim |
|
±10%, single outputs |
 |
Minimum Load |
|
No minimum load required |
 |
Line Regulation |
|
±0.5% max |
 |
Load Regulation |
|
Single output models: ±0.5% max
Dual output models: ±1% max
balanced outputs |
 |
Cross Regulation |
|
±5% for dual outputs, see datasheet - note 2 on datasheet |
 |
Setpoint Accuracy |
|
±1% |
 |
Start Up Time |
|
20 ms typical |
 |
Ripple & Noise |
|
75 mV pk-pk at 20 MHz bandwidth,
see note 3 on datasheet |
 |
Transient Response |
|
3% max deviation, recovery to within
1% in <250 µs for a 25% load change |
 |
Temperature Coefficient |
|
0.02%/°C |
 |
Overvoltage Protection |
|
3.3 V models: 3.9 V typical
5 V models: 6.2 V typical
12 V models: 15 V typical
15 V models: 18 V typical
±5 V models: ±6.2 V typical
±12 V models: ±15 V typical
±15 V models: ±18 V typical |
 |
Overload Protection |
|
>120% of full load typical |
 |
Short Circuit Protection |
|
Trip & restart (Hiccup mode), auto recovery |
 |
Remote On/Off |
|
On = Logic High (3.0-12.0 V) or Open
Off = Logic Low (<1.2 V) or short pin 2 to 6
see note 4 of datasheet |
| |
General |
 |
Efficiency |
|
See datasheet |
 |
Isolation |
|
1600 VDC Input to Output
1600 VDC Input to Case
1600 VDC Output to Case |
 |
Switching Frequency |
|
330 kHz typical |
 |
MTBF |
|
560 kHrs min to MIL-HDBK-217F at 25 ºC, GB |
| |
Environmental |
 |
Operating Temperature |
|
-40 °C to +105 °C, See derating curve on datasheet
|
 |
Case Temperature |
|
+105 °C max |
 |
Cooling |
|
Convection-cooled |
 |
Operating Humidity |
|
5-95% RH, non-condensing |
 |
Storage Temperature |
|
-40 °C to +125 °C |
| |
EMC and Safety |
 |
Emissions |
|
EN55022, class A conducted & radiated with external components - see application notes on datasheet |
 |
ESD Immunity |
|
EN61000-4-2, level 3 Perf Criteria A |
 |
Radiated Immunity |
|
EN61000-4-3 10 V/m, Perf Criteria A |
 |
EFT/Burst |
|
EN61000-4-4 level 3, Perf Criteria B*
(*External input capacitor required 220 µF/100 V) |
 |
Surge |
|
EN61000-4-5 level 2, Perf Criteria B*
(*External input capacitor required 220 µF/100 V) |
 |
Conducted Immunity |
|
EN61000-4-6 10 V/rms, Perf Criteria A |
 |
Magnetic Field |
|
EN61000-4-8 1 A/m, Perf Criteria A
|
 |
Safety Approvals |
|
EN60950-1, IEC60950-1 |