Specifications |
|
| |
Input |
 |
Input Voltage Range |
|
12 V (9-18 VDC)
24 V (18-36 VDC)
48 V (36-75 VDC) |
 |
Input Current |
|
See datasheet |
 |
Input Filter |
|
Pi Network |
 |
Input Reflected Ripple |
|
20 mA pk-pk through 12 µH inductor, 5 Hz to 20 MHz
|
 |
Input Surge |
|
12 V models 36 VDC for 1000 ms,
24 V models 50 VDC for 1000 ms,
48 V models 100 VDC for 1000 ms
|
| |
Output |
 |
Output Voltage |
|
See datasheet |
 |
Output Voltage Balance |
|
±1% max, dual output models
±1% max, dual output models
|
 |
Minimum Load |
|
No minimum load required |
 |
Initial Set Accuracy |
|
±1.2% max |
 |
Start Up Rise Time |
|
<20 ms |
 |
Line Regulation |
|
±0.5% max |
 |
Load Regulation |
|
±0.5% max single, ±1.0% max dual |
 |
Cross Regulation |
|
±5% on dual output models, see datasheet |
 |
Transient Response |
|
<3% deviation, recovery to within 1% in 250 µs for a 25% load change
|
 |
Ripple & Noise |
|
85 mV pk-pk, 20 MHz bandwidth, with 1 µF ceramic capacitor, see note 3 of datasheet
|
 |
Overload Protection |
|
>150% |
 |
Overvoltage Protection |
|
2.5/3.3 V models: 3.9 V typical
5 V models: 6.2 V typical
12 V models: 15.0 V typical
15 V models: 18.0 V typical
±12 V models: ±15.0 V typical
±15 V models: ±18.0 V typical
|
 |
Short Circuit Protection |
|
Trip & restart (hiccup) with auto recovery |
 |
Maximum Capacitive Load |
|
See datasheet |
 |
Remote On/Off |
|
ON >3.0 VDC or open circuit,
OFF <1.2 VDC or short circuit pin 1, 2 & 3 |
 |
Temperature Coefficient |
|
±0.02/°C max
|
| |
General |
 |
Efficiency |
|
See datasheet |
 |
Isolation |
|
1600 VDC Input to Output, 1600 VDC Input to Case, 1600 VDC Output to Case |
 |
Isolation Capacitance |
|
1200 pF max |
 |
Switching Frequency |
|
266 kHz typical |
 |
MTBF |
|
>1.0 MHrs to MIL-HDBK-217F at 25 °C, GB |
| |
Environmental |
 |
Operating Temperature |
|
-40 ºC to +100 ºC, derate from 100% load at +60 °C to no load at +100 °C |
 |
Case Temperature |
|
+100ºC max |
 |
Storage Temperature |
|
-40 ºC to +125 ºC |
 |
Humidity |
|
Up to 90%, non-condensing |
 |
Cooling |
|
Natural convection |
| |
EMC and Safety |
 |
Emissions |
|
EN55022 Class A conducted with external components - see datasheet application notes |
 |
ESD Immunity |
|
EN61000-4-2, 4 kV contact discharge Perf Criteria B |
 |
Radiated Immunity |
|
EN61000-4-3, 3 V/m Perf Criteria A |
 |
EFT/Burst |
|
EN61000-4-4, level 3, Perf Criteria B (see datasheet) |
 |
Surge |
|
EN61000-4-5, level 3, Perf Criteria B (see datasheet) |
 |
Conducted Immunity |
|
EN61000-4-6, 3 Vrms, Perf Criteria A |
 |
Magnetic Field |
|
EN61000-4-8, 1 A/m, Perf Criteria A |