Specifications |
|
| |
Input |
 |
Input Voltage |
|
85-264 VAC (120-370 VDC), derate output
power <90 VAC (See datasheet) |
 |
Input Frequency |
|
47-63 Hz |
 |
Input Current |
|
3.0 A typical at 115 VAC, full load, 1.5 A typical at 230 VAC, full load |
 |
Inrush Current |
|
40 A max at 230 VAC, cold start 25 ºC |
 |
Power Factor |
|
EN61000-3-2, class A |
 |
Earth Leakage Current |
|
200/400 μA 115/230 VAC at 50 Hz, 475 μA 264 VAC at 60 Hz |
 |
Input Protection |
|
Internal T5 A 250 V fuse in line |
| |
Output |
 |
Output Voltage |
|
12-48 V (see datasheet) |
 |
Output Voltage Trim |
|
±5% |
 |
Initial Set Accuracy |
|
±1% V1, ±5% V2, ±3% V3 |
 |
Minimum Load |
|
0.1A required for V2 regulation when used |
 |
Start Up Delay |
|
1.5 s typical, see longform datasheet for
more details |
 |
Start Up Rise Time |
|
5 ms typical |
 |
Hold Up Time |
|
16 ms min at 115 VAC |
 |
Drift |
|
±0.2% after 20 min warm up |
 |
Line Regulation |
|
±0.5% max |
 |
Load Regulation |
|
±1% V1, ±5% V2 & V3 max |
 |
Over/Undershoot |
|
5% typical |
 |
Transient Response |
|
4% max. deviation, recovery to within 1% in 500 μs for a 50-75-50% load change |
 |
Ripple & Noise |
|
1% pk-pk V1, others 2%, 20 MHz bandwidth |
 |
Overvoltage Protection |
|
115-140% Vnom, recycle input to reset |
 |
Overload Protection |
|
110-150% V1 only |
 |
Short Circuit Protection |
|
Continuous trip and restart (Hiccup mode) |
 |
Temperature Coefficient |
|
0.05%/°C |
 |
Remote Sense |
|
Compensates for 0.5 V total voltage drop |
 |
Remote On/Off (Inhibit/Enable Option -A) |
|
Uncommitted isolated optocoupler diode, powered diode inhibits V1 & V2 |
| |
General |
 |
Efficiency |
|
87% typical |
 |
Isolation |
|
3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground |
 |
Switching Frequency |
|
70 kHz typical |
 |
Signals (Option -A) |
|
Power OK - open collector, Remote On/Off, 5 V Standby |
 |
MTBF |
|
390 kHrs per MIL-HDBK-217F at 25 ºC, GB |
 |
Power Density |
|
9.0 W/cubic inch |
| |
Environmental |
 |
Operating Temperature |
|
0 °C to +70 °C derate linearly from +50 °C at 2.5%/°C to 50% load at +70 °C. See datasheet for derating curve and longform datasheet for thermal information. |
 |
Cooling |
|
Forced-cooled >10 CFM |
 |
Operating Humidity |
|
95% RH, non-condensing |
 |
Storage Temperature |
|
-40 °C to +85 °C |
 |
Operating Altitude |
|
3000 m |
 |
Shock |
|
30 g pk, half sine, 6 axes |
 |
Vibration |
|
2 g rms, 5 Hz to 500 Hz, 3 axes |
| |
EMC and Safety |
 |
Low Voltage PSU EMC |
|
EN61204-3, high severity level as below |
 |
Emissions |
|
EN55022 level B conducted, EN55022 level A radiated |
 |
Harmonic Currents |
|
EN61000-3-2, class A |
 |
Voltage Flicker |
|
EN61000-3-3 |
 |
Radiated Immunity |
|
EN61000-4-3, level 3 Perf Criteria A |
 |
EFT/Burst |
|
EN61000-4-4, level 3 Perf Criteria A |
 |
Surge |
|
EN61000-4-5, installation class 3 Perf Criteria A |
 |
Conducted Immunity |
|
EN61000-4-6, level 3 Perf Criteria A |
 |
Dips & Interruptions |
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B |
 |
Safety Approvals |
|
IEC60950-1 CB report, CSA 22.2 No. 60950-1, UL60950-1, TUV EN60950-1 |