Specifications |
|
| |
Input |
 |
Input Voltage Range |
|
See datasheet |
 |
Input Current (No Load) |
|
See datasheet |
 |
Input Reverse Voltage Protection |
|
None |
 |
Input Filter |
|
Pi network |
 |
Undervoltage Lockout |
|
12 Vin, power up 8.8 V, down 8.0 V
24 Vin, power up 17.0 V, down 16.0 V
48 Vin, power up 34.0 V, down 32.5 V
ICH50/75 W:
24 Vin, power up 8.8 V, down 8.0 V
48 Vin, power up 17.0 V, down 16.0 V
|
| |
Output |
 |
Output Voltage Trim |
|
±10% |
 |
Initial Set Accuracy |
|
±1% max |
 |
Line Regulation |
|
±0.2% max measured from high line to low line |
 |
Load Regulation |
|
±0.2%max measured from 0-100% load |
 |
Transient Response |
|
±0.2% max measured from 0-100% load |
 |
Ripple & Noise |
|
2.5, 3.3 & 5 V models: 100 mV pk-pk
12 & 15 V models: 150 mV pk-pk
24, 28 & 48 V models: 1% max pk-pk
ICH50/75 - 2.5 V, 3.3 V, 5 V models: 75 mV
12 V, 15 V models: 100 mV
20 MHz bandwidth, see note 3 of datasheet.
|
 |
Overvoltage Protection |
|
115-140% |
 |
Short Circuit Protection |
|
ICH50/75/100W/150/IFH200-: Trip & restart (Hiccup mode) with auto recovery
ICH50W/75W/100/150 & IFH200: Current limit, auto recovery
|
 |
Temperature Coefficient |
|
±0.03%/°C |
 |
Current Limit |
|
IFH200: 110-150% nominal output,
all other models: 110-140% nominal output
|
 |
Remote On/Off |
|
See datasheet |
 |
Thermal Shutdown |
|
ICH50/50W/75/75W/100/150:
Thermal shutdown when case temperature reaches 100 ºC, auto recovery when case temperature <+60 ºC
ICH100W/150W/IFH200:
Thermal shutdown when case temperature reaches 105 ºC, auto recovery when case temperature <+90 ºC |
| |
General |
 |
Efficiency |
|
See datasheet |
 |
Isolation Voltage |
|
1500 VDC Input to Output
1500 VDC Input to Case
1500 VDC Output to Case |
 |
Isolation Resistance |
|
10(9) Ohms min |
 |
Switching Frequency |
|
ICH50/75 12-24V models: 400 kHz typical
ICH50/75 48 V models: 300 kHz typical
ICH50W/75W: 300 kHz typical
ICH100/ICH150: 500 kHz typical
IFH200: 350 kHz typical |
 |
MTBF |
|
≥790 kHrs to MIL-HDBK-217F at 25 ºC, GB |
| |
Environmental |
 |
Operating Case Temperature |
|
-40 °C to +100 °C, see derating curve of datasheet
|
 |
Storage Temperature |
|
ICH50/75: -55 °C to +105 °C
ICH100/150 & IFH200: -40 °C to +105 °C |
 |
Shock |
|
30 g pk, half sine wave for 18 ms, 3 pulses per face, all 6 faces tested on all 3 axes
|
 |
Vibration |
|
5-500 Hz at 3g, 10 mins per axis
|
| |
EMC and Safety |
 |
Emissions |
|
EN55022, level A conducted |
 |
ESD Immunity |
|
EN61000-4-2, level 2 Perf Criteria B |
 |
Radiated Immunity |
|
EN61000-4-3, 3 V/m Perf Criteria B
|
 |
Conducted Immunity |
|
EN61000-4-6, 3 V rms Perf Criteria B |
 |
Safety Approvals |
|
UL60950-1 (ICH100W not UL approved)
|