Input Transient |
|
10-50 V for 10 s
600 V for 10 µs 50 Ω source resistance per
MIL-STD-704A, 100 V for 50ms 0.5 Ω source resistance per MIL-STD-1275A, ±250 V for 100 µs as per MIL-STD-1275A
|
 |
Inhibit |
|
Off = TTL Low or short circuit, On = TTL High or open circuit |
 |
Resistance |
|
0.25 Ω input to output, <0.1 Ω case to case pin at 10 A |
 |
Power Dissipation Inhibited |
|
0.1 W |
 |
MTBF |
|
846 kHrs to MIL-HDBK-217F at +40 °C, GF |
 |
Operating Temperature |
|
-40 °C to +85 °C ambient
-40 °C to +100 °C case
Extended Temperature Range: (option -LT)
-55 °C to +85 °C ambient
-55 °C to +100 °C case |
 |
Operating Altitude |
|
Tested to 70000 ft (21336 m) |
 |
Operating Humidity |
|
88% relative humidity 240h MIL-STD-810D Method 507.2 |
 |
Shock |
|
100 g MIL-STD-810D Method 516.3 |
 |
Vibration |
|
10 to 2000Hz MIL-STD-810D Method 514.3 |
 |
Bump |
|
2000 Bumps in each axes, 40 g MIL-STD-810D Method 516.3 |
 |
Salt Atmosphere |
|
48 hours MIL-STD-810E Method 509.1 |
 |
Conducted Emissions |
|
EN55022 Conducted Level B.
MIL-STD-461E/F, CE101 & CE102 |
 |
Immunity |
|
MIL-STD-704E, MIL-STD 704A &
MIL-STD-1275A/B/C/D
|
 |
Conducted Susceptibility |
|
MIL-STD-461E/F, CS101, CS114, CS115 & CS116
|
 |
|
|
EMC standards are met when used in conjuction with the MTC series of DC/DC converters |