Specifications |
|
| |
Input |
 |
Input Voltage Range |
|
15.5-40.0 VDC |
 |
Transient Input Range |
|
10 VDC maximum load for 10 s, 50 VDC for 1 s at full load |
 |
Turn On |
|
<15.5 VDC |
 |
Turn Off |
|
<10 VDC |
 |
Input Reverse Voltage Protection |
|
None |
 |
Max Input Current |
|
See datasheet |
| |
Output |
 |
Output Voltage |
|
See datasheet |
 |
Output Voltage Trim |
|
See datasheet |
 |
Minimum Load |
|
No minimum load required |
 |
Line Regulation |
|
±1% Vout nominal (15.5-40.0 Vin) |
 |
Load Regulation |
|
±1% Vout nominal |
 |
Cross Regulation |
|
±3% with 150 mA min load (Dual output only) see longform datasheet for more information |
 |
Output Set Tolerance |
|
±100 mV or ±2% whichever is greater |
 |
Ripple & Noise |
|
≤5 Vout: 60 mV pk-pk max,
>5 Vout: 1% pk-pk, at max load & 20 MHz bandwidth |
 |
Overvoltage Protection |
|
110-120% Vout max (15 W & 30 W versions only)
|
 |
Overcurrent Protection |
|
105-150% at nominal input voltage |
 |
Overtemperature Protection |
|
102 °C to 107 °C, 2 °C to 5 °C hysteresis
|
 |
Remote Sense |
|
0.5 V (Single output only) |
 |
Load Step Output Transient |
|
<±3% of Vout nom (25-75% load) |
 |
Load Step Recovery |
|
500 µs within 1% of nominal value |
 |
Line Step Output Transient |
|
<±3% of nominal Vout (15.5-40.0 Vin) |
 |
Line Step Recovery |
|
500 µs within 1% of nominal value |
 |
Start Up Time |
|
<100 ms |
 |
Max Capacitive Load |
|
300 µF x Iout max startup within 100 ms |
| |
General |
 |
Efficiency |
|
See tables and performance curves on datasheet |
 |
Isolation |
|
1500 VDC Input to Output, 1000 VDC Input to Case, 500 VDC Output to Case |
 |
Switching Frequency |
|
Fixed 450 kHz typical |
 |
Frequency Synchronisation |
|
400-500 kHz |
 |
Inhibit |
|
Off = TTL Low or short circuit, On = TTL High or open circuit |
 |
MTBF |
|
MTC05: 1.7 MHrs, MTC15: 890 kHrs
MTC30: 740 kHrs, to MIL-HDBK-217F at +40 °C, GF |
| |
Environmental |
 |
Case Temperature |
|
-40 °C to +100 °C, extended range ‘-LT’: -
55 °C to +100 °C, MTC05 limited to 80%
load below -40 ºC |
 |
Operating Humidity |
|
88% Relative Humidity 240h MIL-STD-810D Method 507.2 |
 |
Storage Temperature |
|
-50 °C to + 125 °C |
 |
Operating Altitude |
|
Tested to 70000 ft (21336 m) |
 |
Shock |
|
100 g MIL-STD-810D Method 516.3 |
 |
Vibration |
|
10 to 2000 Hz MIL-STD-810D Method 514.3 |
 |
Bump |
|
2000 Bumps in each axes 40 g MIL-STD-810D Method 516.3 |
 |
Salt Atmosphere |
|
48 hours MIL-STD-810E Method 509.1 |
| |
EMC and Safety |
 |
Conducted Emissions |
|
EN55022 Conducted Level B*
MIL-STD 461E/F CE102*
DEF STAN 59-41: DCE01/DCE02*
(* MTF50 Filter Module recommended to meet these standards) |
 |
Immunity |
|
MIL-STD-704 A*, MIL-STD-704 B-F
MIL-STD-1275A/B/C/D*
(* MTF50 Filter Module recommended to meet these standards) |
 |
Conducted Susceptibility |
|
MIL-STD-461E/F CS101, CS114,CS115,CS116*
(* MTF50 Filter Module recommended to meet these standards) |