SMM400 Series

   
SMM400 Series • 400 Watts
• Industrial, IT & Medical Approvals
• Low Profile for 1U Applications
• Optional Current Share & AC Fail
• Output Voltages from 3.3 V to 54 V
• 3 Year Warranty

Click Here for Model Numbers & Stock Check
Specifications  
 
Input
Input Voltage   90-264 VAC (120-370 VDC)
Input Frequency   47-63 Hz
Input Current   6.35 A at 90 VAC, full load
Inrush Current   35 A peak max (cold start at 230 VAC & full load)
Power Factor   EN61000-3-2 class A EN61000-3-2 class C for loads ≥40%
Earth Leakage Current   <300 µA max at 264 VAC/60 Hz
UVLO   Shut down when 75 VAC 86 VAC
Input Protection   Internal T8 A/250 VAC fuse in line and neutral
 
Output
Output Voltage   3.3 to 54 VDC - see tables on datasheet
Output Voltage Trim   ±5% on V1
Initial Set Accuracy   Within 1% of stated output voltage
Minimum Load   Single output: 1%. Dual output (V1): 10%
Start Up Delay   2 s max at 120 VAC
Hold up Time   20 ms min at 80% full load
Line Regulation   0.5%
Load Regulation   ±1% (single outputs), ±3% V1, ±7% V2 (dual outputs)
Over/Undershoot   Not to exceed 5% of nominal voltage
Transient Response   5% max deviation, recovery to within 1% in 500 µs for a 50% load change
Ripple & Noise   <1% of nominal output voltage, measured using 0.1 µF ceramic and 22 µF electrolytic capacitor, 20 MHz bandwidth.
Overvoltage Protection   130% Vnom, recycle input to reset
Overtemperature Protection   Shuts down at +85 °C, measured internally with auto recovery
Overload Protection   110-140%
Short Circuit Protection   Constant current, auto recovery
Remote Sense   Compensates for up to 0.5 V drop (not available with current share)
Remote On/Off   On = TTL Logic High or Open, Off = TTL Logic Low or Short
Current Share   Option ‘-I’ available on single output models only - see note 5 of datasheet
Fan Drive   12 V at 400 mA
 
General
Efficiency   3.3 & 5.0 V single output: 70% min, All other single output: 80% min, Dual outputs: 75% min at 230 VAC, full load
Isolation   4000 VAC Input to Output, 1500 VAC Input to Ground, 250 VDC Output to Ground
Switching Frequency   30 kHz PWM, 60 kHz PFC typical
Power Density   6.25 W/In3
Signals   Power Good & Current Monitor as standard. AC Fail & Current Share are optional (see notes on datasheet)
MTBF   140 kHrs to MIL-HDBK-217F at 25 °C, GB
 
Environmental
Operating Temperature   -0 °C to +70 °C, derate linearly from +50 °C to+ 70 °C at 2.5%/°C
Cooling   ‘-C’ version has built-in fan, others require 23 CFM air flow to meet fan-cooled ratings
Operating Humidity   5-90% RH, non-condensing
Storage Temperature   -20 °C to +85 °C
Vibration   5-50 Hz, acceleration 2 g, 3 minute sweep, 60 mins in 3 axes
Shock   15 g 11 ms 1/2 sine wave, 3 times in 6 axes
Bump   15 g 6 ms 1/2 sine 4000 bumps on 3 axes
 
EMC and Safety
Emissions   EN55011/22 Level B conducted & radiated
Harmonic Currents   EN61000-3-2 class A EN61000-3-2 class C for loads ≥40%
Voltage Flicker   EN61000-3-3
ESD Immunity   EN61000-4-2, level 3 Perf Criteria A
Radiated Immunity   EN61000-4-3, 3 V/m Perf Criteria A
EFT/Burst   EN61000-4-4, level 2 Perf Criteria A
Surge   EN61000-4-5, installation class 3 Perf Criteria A
Conducted Immunity   EN61000-4-6, 3 V, Perf Criteria A
Safety Approvals   UL60601-1, EN60601-1, EN60950-1:2001, UL60950, CSA C22.2 No. 60950-1-03, CSA C22.2 No. 601.1-M90
Dips & Interruptions   EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B
           
Model Number
Input
Output
Power
       
  SMM400PS03 90-264 VAC 3.3V/45A 148.5 W 
  SMM400PS03-C 90-264 VAC 3.3V/45A 148.5 WStock Check
  SMM400PD21 90-264 VAC 3.3 V/30.0 A, 12.0 V/16.7 A 200 W 
  SMM400PD21-C 90-264 VAC 3.3 V/30.0 A, 12.0 V/16.7 A 200 W 
  SMM400PD22 90-264 VAC 3.3 V/30.0 A, 24.0 V/8.30 A 200 W 
  SMM400PD22-C 90-264 VAC 3.3 V/30.0 A, 24.0 V/8.30 A 200 W 
  SMM400PD23 90-264 VAC 5.0 V/30.0 A, 12.0 V/16.7 A 200 W 
  SMM400PD23-C 90-264 VAC 5.0 V/30.0 A, 12.0 V/16.7 A 200 W 
  SMM400PD24 90-264 VAC 5.0 V/30.0 A, 24.0 V/8.30 A 200 W 
  SMM400PD24-C 90-264 VAC 5.0 V/30.0 A, 24.0 V/8.30 A 200 W 
  SMM400PS05 90-264 VAC 5V/45A 225 W 
  SMM400PS05-C 90-264 VAC 5V/45A 225 WStock Check
  SMM400PD25 90-264 VAC 12.0 V/16.7 A, 24.0 V/8.30 A 250 W 
  SMM400PD25-C 90-264 VAC 12.0 V/16.7 A, 24.0 V/8.30 A 250 W 
  SMM400PS12 90-264 VAC 12V/20.8A 250 W 
  SMM400PS12-C 90-264 VAC 12V/20.8A 250 WStock Check
  SMM400PS15 90-264 VAC 15V/16.6A 250 W 
  SMM400PS15-C 90-264 VAC 15V/16.6A 250 WStock Check
  SMM400PS18 90-264 VAC 18V/13.9A 250 W 
  SMM400PS18-C 90-264 VAC 18V/13.9A 250 W 
  SMM400PS24 90-264 VAC 24V/10.4A 250 W 
  SMM400PS24-C 90-264 VAC 24V/10.4A 250 WStock Check
  SMM400PS27 90-264 VAC 27V/9.2A 250 W 
  SMM400PS27-C 90-264 VAC 27V/9.2A 250 W 
  SMM400PS36 90-264 VAC 36V/6.9A 250 W 
  SMM400PS36-C 90-264 VAC 36V/6.9A 250 W 
  SMM400PS48 90-264 VAC 48V/5.2A 250 W 
  SMM400PS48-C 90-264 VAC 48V/5.2A 250 WStock Check
  SMM400PS54 90-264 VAC 54V/4.6A 250 W 
  SMM400PS54-C 90-264 VAC 54V/4.6A 250 W 
           


Defence & Avionics Communications Medical

Industrial