Specifications |
|
| |
Input |
 |
Input Voltage |
|
90-264 VAC |
 |
Input Frequency |
|
47-63 Hz |
 |
Inrush Current |
|
40 A max at 230 VAC, cold start 25 ºC |
 |
Power Factor |
|
Compliant with EN61000-3-2, Class A
|
 |
Earth Leakage Current |
|
<1.5 mA |
 |
Input Protection |
|
F3/FF: Internal T6.3 A/250 V fuse in line
F4/F6: Internal T10 A/250 V fuse in line
F7: Internal T12 A/250 V fuse in line
F8: Internal T15 A/250 V fuse in line
FX: Internal T20 A/250 V fuse in line
|
| |
Output |
 |
Output Voltage |
|
See datasheet |
 |
Output Voltage Trim |
|
±5% typical all outputs |
 |
Hold Up Time |
|
20 ms min |
 |
Line Regulation |
|
Typically 0.1%, maximum 0.3% |
 |
Load Regulation |
|
1% max for single output modules & V1 of dual & triple output modules. 2% max for V2 & V3 of dual & triple output modules. The E module requires up to 10% load & the K module up to 5% load on V1 to achieve the specified regulation figures on V2 & V3 |
 |
Ripple and Noise |
|
50 mV or 1% pk-pk, whichever is greater, 20 MHz bandwidth |
 |
Overvoltage Protection |
|
115-130% Vnom for single output and output 1 of dual & triple output modules. No OVP fitted to G modules or H modules.
|
 |
Overload Protection |
|
<140% of nominal rating |
 |
Short Circuit protection |
|
Continuous trip & restart (Hiccup mode) |
 |
Temperature Coefficient |
|
0.03%/°C |
 |
Remote Sense |
|
See signals & controls page on datasheet |
 |
Current Share |
|
Single wire parallel current share. See signals & controls page on datasheet |
 |
Inhibit |
|
TTL compatible. See signals & controls page on datasheet |
| |
General |
 |
Efficiency |
|
75% typical at nominal input |
 |
Isolation |
|
3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground |
 |
Signals & Controls |
|
AC OK, DC OK, Current share, Global Inhibit, Module Inhibit, Remote Sense, Voltage Programming & 5V Standby
|
 |
MTBF |
|
750 kHrs demonstrated |
| |
Environmental |
 |
Operating Temperature |
|
0 °C to +70 °C, derate linearly from 100% at +50 °C to 50% at +70 °C for standard models. Derate linearly from 100% at
+40 °C to 50% at +60 °C for reverse
air models.
|
 |
Storage Temperature |
|
-40 °C to +85 °C |
 |
Operating Altitude |
|
3000 m |
 |
Shock |
|
30 g, 11 ms (half sine), 3 shocks each axis, 18 shocks total. Compliant with EN60068-2-27
|
 |
Vibration |
|
2 g, 10-500 Hz, 10 sweeps 3 axes. Compliant with EN60068-2-6
|
| |
EMC and Safety |
 |
Emissions |
|
EN55022, Level B conducted |
 |
ESD Immunity |
|
EN61000-4-2, Level 3 Perf Criteria A |
 |
Radiated Immunity |
|
EN61000-4-3, Level 3 Perf Criteria A |
 |
EFT/Burst |
|
EN61000-4-4, Level 3 Perf Criteria A |
 |
Surge |
|
EN61000-4-5, Level 3 Perf Criteria A |
 |
Conducted Immunity |
|
EN61000-4-6, Level 3 Perf Criteria A |
 |
Dips & Interruptions |
|
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B |
 |
Safety Approvals |
|
EN60950, UL60950, CSA22.2-No 950 CE Mark LVD, SEMI F47 compliant (high line only) |
 |
Harmonic Currents |
|
EN61000-3-2, Class A |
 |
Voltage Flicker |
|
EN61000-3-3 |